UL2464什麽意思
Style 2464 Jacketed Cable.
Rating 80 deg C, 300 Vac, Cable flame.
Insulation Labeled or complying with manufacturer's AWM Procedure.
Assembly Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Shield Optional.
Covering Optional.
Braid Optional, provided over Jacket.
Jacket PVC
Dia of Cable under jacket Min average Minimum at any point
0.700 inch or less 30 mils 24 mils
0.701-1.000 inch 45 mils 36 mils
1.001-1.500 inch 60 mils 48 mils
1.501-2.500 inch 80 mils 64 mils
2.501-4.000 inch 110 mils 88 mils
4.001 inch and larger 140 mils 112 mils
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or x-ray equipment).